Study of the influence of bubbles on electromagnetic flow measurement
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

TH814

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The electromagnetic flowmeter plays an important role in the industrial production. However, easily influenced by the bubbles in the fluid, fluctuations often appear in the measurement results, leading to a lower measurement accuracy. Quantitative analysis of the influence of bubbles in the electromagnetic flowmeter measurement process has important engineering significance for improving the accuracy of electromagnetic flow measurement and realizing gas-liquid two-phase flow measurement. In view of this, starting with the weight function, the analytic method is used to establish the theoretical model of bubble size, bubble eccentricity, and the number of bubbles. Then, by simulation and experiments, the influence of different states of bubbles on the electromagnetic flow system with a diameter of 100 mm and circular point electrodes with a 5 mm radius is studied. The output voltage sensitivity is used to analyze the influence of different states of bubbles on electromagnetic flow measurement. According to the research results, with the increasing of the bubble size, its impact on the electromagnetic flow measurement is within the range of 0. 3% ~ 5%, the maximum of 5%. The influence of bubbles with a diameter of 10 mm ranges within 0. 25% ~ 0. 6% along the eccentricity direction of the electrode and increases with the increasing of the eccentricity distance. The influence of the increasing eccentric distance along the direction perpendicular to the electrode has a tiny impact on the measurement. It fluctuates within - 0. 2% ~ 0. 2%. Meanwhile, with the bubble flow, a shorter distance between the bubbles and the electrode cross-section leads to a larger impact while the impact gets its maximum at the electrode cross-section. The maximum values for a single bubble are 0. 18%, 0. 22%, -0. 20%. The influence is enhanced with the increasing in the number of bubbles. The maximum values in the case of 3 bubbles and 6 bubbles are 0. 36% and 2. 3%. This paper improves the theories related to the weight function of electromagnetic measurement of gas and fluid double-phase flow, obtains the influences of different states of bubbles on the electromagnetic flow measurement system, and provides technical support for the improvement of electromagnetic flow measurement accuracy and realization of gas and fluid double-phase flow.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: March 06,2023
  • Published:
Article QR Code