李胤演,行鸿彦.地表相对介电常数对雷暴云定位影响分析与研究[J].电子测量与仪器学报,2022,36(6):187-195
地表相对介电常数对雷暴云定位影响分析与研究
Analysis and research on the influence of the relative permittivity of theearth surface on thunderstorm cloud positioning
  
DOI:
中文关键词:  大气电场测量  地表相对介电常数  雷暴云定位  大气电场仪
英文关键词:atmospheric electric field measurement  relative permittivity  thunderstorm cloud positioning  atmospheric electric field measuring instrument
基金项目:国家重点研发计划(2021YFE0105500)、国家自然科学基金(62171228)项目资助
作者单位
李胤演 1.南京信息工程大学江苏省气象灾害预报预警与评估协同创新中心 
行鸿彦 1.南京信息工程大学江苏省气象灾害预报预警与评估协同创新中心 
AuthorInstitution
Li Yinyan 1.Jiangsu Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters, Nanjing University of Information Science & Technology 
Xing Hongyan 1.Jiangsu Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters, Nanjing University of Information Science & Technology 
摘要点击次数: 446
全文下载次数: 990
中文摘要:
      地表并非均匀介质的理想导体,传统的一维大气电场分量无法准确的对雷暴云进行定位,而利用大气电场三维场强分 量进行雷暴云定位时,电场的场强、雷暴云的高度角测量往往会受到地表及空气介电常数的影响,产生定位误差。 为解决雷暴 云定位精度低的问题,分析了三维大气电场对于地表相对介电常数的敏感特性,结合镜像法,利用空中电荷电场分布、雷暴云电 荷结构等原理,建立了雷暴云定位模型,分析得到大气电场场强、高度角与环境相对介电常数的关系。 实验结果表明,地表相对 介电常数越大,所测得的电场水平分量与雷暴云高度角越大,地表相对介电常数与大气电场水平分量的相关系数为-9. 5,呈负 相关,相关性强,因此要获得准确的雷暴云高度及方位,还须实时的地表相对介电常数进行修正。
英文摘要:
      The ground surface is not an ideal conductor of a homogeneous medium. The traditional one-dimensional atmospheric electric field component cannot accurately locate the thunderstorm cloud. When the three-dimensional field intensity component of the atmospheric electric field is used to locate the thunderstorm cloud, the field strength of the electric field and the altitude angle of the thunderstorm cloud are often measured. The electric field will be affected by the dielectric constant of the ground and air, resulting in positioning errors. In order to solve the problem of low positioning accuracy of thunderstorm clouds, this paper analyzes the sensitive characteristics of the three-dimensional atmospheric electric field to the relative permittivity of the surface, combined with the mirror image method, and establishes a thunderstorm cloud positioning model using the principles of electric field distribution in the air and the charge structure of thunderstorm clouds. Analyze the relationship between the atmospheric electric field strength, altitude angle and the relative permittivity of the environment. The experimental results show that the greater the relative permittivity of the surface, the greater the measured electric field horizontal component and the height angle of the thunderstorm cloud. The correlation coefficient between the relative permittivity of the surface and the horizontal component of the atmospheric electric field is -9. 5, showing a negative correlation. Therefore, to obtain the accurate height and azimuth of the thunderstorm cloud, the relative permittivity of the ground surface must be corrected in real time.
查看全文  查看/发表评论  下载PDF阅读器