乔卫东,李 跃,郭 梁.航空航天相机成像性能测试系统研究[J].电子测量与仪器学报,2020,34(9):9-16
航空航天相机成像性能测试系统研究
Development of device for imaging performance test of aerospace camera
  
DOI:
中文关键词:  航空航天相机  成像性能  千兆以太网  调制传递函数  对比度法
英文关键词:aerospace cameras  imaging performance  gigabit ethernet  modulation transfer function  contrast method
基金项目:国家重点研发计划项目(2018YFF0212105)、西安市科技计划项目(201805037YD15CG21(27))资助
作者单位
乔卫东 1.西安理工大学 机械与精密仪器工程学院 
李 跃 1.西安理工大学 机械与精密仪器工程学院 
郭 梁 1.西安理工大学 机械与精密仪器工程学院 
AuthorInstitution
Qiao Weidong 1.School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology 
Li Yue 1.School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology 
Guo Liang 1.School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology 
摘要点击次数: 632
全文下载次数: 788
中文摘要:
      在航空航天相机的研制过程中,为了测试与评估其整机系统的成像性能,针对相机高分辨率、高量化位数和高帧频的特 点,研究开发了一套基于千兆以太网的航空航天相机成像性能的测试系统。 在测试系统中应用 FPGA 完成千兆以太网协议实 现图像数据的高速传输,通过上位机实时显示图像并进行图像处理与计算,经过对调制传递函数的理论分析,确定采用对比度 法计算获得相机的调制传递函数(MTF)。 实验验证了图像数据实时显示的可行性与图像数据传输的正确性,同时使用 3 种不 同型号的相机获取了不同分辨率 2 048×2 049、2 564×2 162、2 045×256 的测试图像的 MTF 值,通过获取 3 组数据的标准差,并 与传统人工测试方法的对比分析,实验表明,该测试装置大幅提高了测试效率和测试精度,实现了整体系统成像性能的实时 评价。
英文摘要:
      In the aerospace camera development process, in order to test and evaluate the imaging performance of its complete system, a set of test system for the imaging performance of aerospace cameras based on Gigabit Ethernet has been developed aiming at the characteristics of high resolution, high quantization digits and high frame rate. In the test system, FPGA is used to complete the Gigabit Ethernet protocol to achieve the high-speed transmission of image data, the image is displayed in real time by the host computer. Then image processing and calculation are performed, after theoretical analysis of the modulation transfer function, it is determined that the contrast method is used to calculate the modulation transfer function of the camera (MTF). The experiments have verified the feasibility of real-time display of image data and the correctness of image data transmission, at the same time, the MTF values of test images with different resolutions of 2 048× 2 049, 2 564× 2 162, and 2 045× 256 were obtained by using three different models of cameras, the standard deviations of the three sets of data were obtained and compared with traditional manual test methods. The experiment shows that the test device greatly improves the test efficiency and test accuracy, it realizes the real-time evaluation of the overall system imaging performance.
查看全文  查看/发表评论  下载PDF阅读器